84270Q
1.INSPECT LIGHT CUT RELAY (for LHD)
Detach the clamp.
Remove the light cut relay.
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the light cut relay.
Install the light cut relay.
84270Q
2.INSPECT LIGHT CUT RELAY (for RHD)
Remove the combination meter assembly.
Remove the light cut relay.
Check the resistance.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 - 5 | Battery voltage not applied to terminals 1 and 2 | 10 kΩ or higher |
| Battery voltage applied to terminals 1 and 2 | Below 1 Ω |
If the result is not as specified, replace the light cut relay.
Install the light cut relay.
Install the combination meter assembly.